日本性感染症学会誌 Journal of Japanese Society for Sexually Transmitted Infections

Online ISSN: 2434-2505 Print ISSN: 0917-0324
日本性感染症学会 Japanese Society for Sexually Transmitted Infections
〒162-0801東京都新宿区山吹町358-5アカデミーセンター Japanese Society for Sexually Transmitted Infections Academy Center, 358-5 Yamabuki-cho, Shinju-ku, Tokyo 162-0801, Japan
Japanese Journal of Sexually Transmitted Infections 36(3): 67-71 (2025)
doi:10.24775/jjsti.O-2025-0012

原著原著

当院におけるChlamydia trachomatisおよびNeisseria gonorrhoeae核酸増幅法の検査体制変更による効果と影響についてEffects and impact of changing the nucleic acid amplification testing system for Chlamydia trachomatis and Neisseria gonorrhoeae in our hospital

1札幌医科大学附属病院検査部Division of Laboratory Medicine, Sapporo Medical University Hospital

2札幌医科大学医学部感染制御・臨床検査医学講座Department of Infection Control and Laboratory Medicine, Sapporo Medical University School of Medicine

受付日:2025年5月19日Received: May 19, 2025
受理日:2025年8月20日Accepted: August 20, 2025
発行日:2026年1月13日Published: January 13, 2026
HTMLPDFEPUB3

当院のChlamydia trachomatisおよびNeisseria gonorrhoeae核酸増幅法の検査体制変更の効果と影響について報告する。外部検査機関に委託して実施した時期をI期、院内でcobas 6800システムを用いて検査を実施した時期をII期、GeneXpertシステムGX-XVIで実施した時期をIII期として解析した。検査結果判明までの時間の中央値は、それぞれ54時間21分(I期)、69時間55分(II期)、1時間38分(III期)と、リアルタイム処理型の測定機器に変更したことで大幅に短縮し、1件当たりの検査コストも57%削減できた。cobas 6800システムとGeneXpertシステムGX-XVIの判定一致率はC. trachomatisで97.5%、N. gonorrhoeaeでは100%であった。検査体制の変更によって検査性能の質を落とすことなく、有益な効果を得ることができた。

We report the impact of changing the nucleic acid amplification testing system for Chlamydia trachomatis and Neisseria gonorrhoeae in our hospital. Three testing phases were analyzed in terms of turnaround time and cost: Phase I, outsourced testing; Phase II, in-house testing using the cobas 6800 system; and Phase III, in-house testing using the GeneXpert system GX-XVI. Median turnaround times were 54 hours and 21 minutes (Phase I), 69 hours and 55 minutes (Phase II), and 1 hour and 38 minutes (Phase III). Switching to the GeneXpert system XVI significantly reduced turnaround time, and the cost per test decreased by 57% from Phase II to Phase III. The overall agreement between the cobas 6800 system and the GeneXpert system XVI was 97.5% for C. trachomatis and 100% for N. gonorrhoeae. These findings demonstrate that the new testing system improved efficiency while maintaining testing quality in our hospital.

Key words: Chlamydia trachomatis; Neisseria gonorrhoeae; Xpert CT/NG; cobas CT/NG; turnaround time

This page was created on 2025-10-22T16:55:01.853+09:00
This page was last modified on 2026-01-06T14:56:22.000+09:00